What was the problem electronic turnstile gate easy have after many years used

As the fast-track gates commonly used by the public, the stable and safe operation of  electronic turnstile gate are related to the safety of the lives and properties of users. With the frequent occurrence of elevator accidents in Shenzhen recently, in addition to regretting the lives lost in the accident, there are also higher requirements for the safety of the public equipment we use, such as tripod turnstile Gate and swing turnstile gate.
tripod turnstile Gate and swing turnstile gate, during the usual installation and use process, if you follow the operating specifications and carry out professional maintenance, generally there will be no failures, but the fast-track gates such as three-roll gates and swing gates are machines after all. Factors such as the increase in use time, the wear of the workpiece, the irregular operation and other factors will cause some failures. The common failures and treatment methods of the three-roll gate and the swing gate are summarized as follows:
Common faults of tripod gate and swing gate during ticket checking:
1: Three roller gates and swing gates cannot enter after swiping or checking the ticket
1. Pedestrians may have withstood the rotating rod when swiping the card or checking the ticket. Please take a step back and enter.
2. Please check whether the electromagnet is normal. If the voltage of the electromagnet is output in the control part, and the voltage is normal, but the electromagnet cannot be picked up, just replace the electromagnet.
2. Several people can pass continuously after swiping the card or checking the ticket
1. Check whether the proximity switch and the induction screw on the proximity switch bracket are loose. Under normal circumstances, when a person passes normally, the induction screw will contact the induction proximity switch, and the induction lamp on the induction proximity switch will light up. If the light is not on, use a multimeter to measure whether the input power of the proximity switch is normal. If it is normal, replace the proximity switch.
2. In the case that the proximity switch is not broken and the card is read, check whether the electromagnet is reset. If not, remove the electromagnet, check whether there is any foreign matter inside the electromagnet and deal with it. If there is no foreign matter, the spring inside the electromagnet can be increased, but not too much, too much will cause the electromagnet to fail to attract.
3. No response when swiping the card
1. Check whether the ticket used is the ticket of this system and whether the ticket verification method is correct.
2. Check whether the connection of the card reader is normal, if it is a barcode ticket, please check whether the card is inserted backwards, check whether the connection of the card reader unit is normal, and whether the angle of the barcode reader is accurate.
3. Check whether the key trigger board is normal.
4. The response speed of ID card is slow when swiping
1. The parameter setting is wrong, the problem is solved after correct setting
Rotary rod failure during operation of three-roller gate and swing gate:
1. Three roller gates, the rotating rod cannot be lifted after the swing gate is energized
1. Press the rotating rod down to the end and then lift it up.
2. Open the cover of the gate, check whether the circlip on the electromagnet device of the lever falls off, whether the circlip is in close contact with the electromagnet when the lever is pressed to the end, if not, you need to readjust the installation position of the electromagnet.
3. Check whether the electromagnet is damaged. Use a multimeter to measure whether there is a supply voltage (24V). If there is a voltage, there is no problem in the above inspections, please replace the electromagnet; if there is no voltage, please check whether the output part of the control drive board is normal.
2. A few turnstiles have been dropped
1. The position of the pole drop solenoid is not installed properly, install it in the correct way.
2. Power supply problem, insufficient voltage, overhaul the circuit to ensure that the voltage is normal.
Three, the turnstiles are powered off but the poles are not dropped
1. Check whether the installation position of the electromagnet is correct, and the spring force of the falling pole electromagnet bracket is too small, adjust it in time.
2. The friction between the turntable and the rotating rod is too large, and the maintenance should be carried out according to the maintenance guide during normal maintenance.
Turntable failure during operation of three-roller gate and swing gate
1. Imported machine turntable can sometimes be reversed
Under normal circumstances, you can only enter after checking a valid ticket, and you cannot reverse it. If reversal occurs:
1. Check whether the stop pin is reset. First open the gate cover, add some lubricating oil to the stop pin, and then pull the stop pin back and forth to make it completely lubricated. You can also remove the car stop bracket, take out the car stop pin and clean the burrs with a file, then assemble it back, add liquid lubricant, and pull the car stop pin back and forth to make it fully movable.
2. It may be that the performance of the buffer is unstable and the turntable cannot be reset. You can adjust the strength of the buffer or replace the buffer.
3. The position of the proximity switch is incorrect, and the turntable cannot be reset, so you need to adjust the position of the proximity switch.
2. The turntable swings up and down
1. The tray of the movement turntable is loose and the gap between the fits is too large. Adjust the gap.
2. If the tray screws are loose, tighten the screws in time.